ProLiant ML350 Maintenance and Service Guide Fourth Edition (March 2002) Part Number 122832-004 Spare Part Number 164275-001 Compaq Computer Corp
1-2 Compaq ProLiant ML350 Maintenance and Service Guide Mechanical Parts Exploded View 5813c23b3a4b964a97 Figure 1-1. Mechanical parts exploded vi
Diagnostics and Troubleshooting 3-45 800 – 899, Video Board Test Error Codes The 800 series of diagnostic error codes identifies failures with video
3-46 Compaq ProLiant ML350 Maintenance and Service Guide 1200 – 1299, Modem Communications Test Error Codes The 1200 series of diagnostic error codes
Diagnostics and Troubleshooting 3-47 1700 – 1799, Hard Drive Test Error Codes The 1700 series of diagnostic error codes identifies failures with hard
3-48 Compaq ProLiant ML350 Maintenance and Service Guide 1900 – 1999, Tape Drive Test Error Codes The 1900 series of diagnostic error codes identifie
Diagnostics and Troubleshooting 3-49 Table 3-14 Advanced VGA Board Test Error Codes continued Error Code Description Recommended Action 2410-xx Vi
3-50 Compaq ProLiant ML350 Maintenance and Service Guide 6500 – 6599, SCSI Hard Drive Test Error Codes The 6500 series of diagnostic error codes iden
Diagnostics and Troubleshooting 3-51 6700 – 6799, SCSI Tape Drive Test Error Codes The 6700 series of diagnostic error codes identifies failures with
3-52 Compaq ProLiant ML350 Maintenance and Service Guide Array Diagnostic Utility (ADU) The Array Diagnostic Utility (ADU) is a Windows-based softwar
Diagnostics and Troubleshooting 3-53 Table 3-19 ADU Diagnostic Messages Message Description Recommended Action Accelerator board not detected Array
3-54 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Acceler
Illustrated Parts Catalog 1-3 Mechanical Spare Parts List Table 1-1 Mechanical Spare Parts List Item Description Spare Part Number Chassis 1
Diagnostics and Troubleshooting 3-55 Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Adapter/NVRAM ID mismatch E
3-56 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Control
Diagnostics and Troubleshooting 3-57 Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Drive (bay) X is a replacem
3-58 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Error o
Diagnostics and Troubleshooting 3-59 Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Logical Drive X status = FA
3-60 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Loose c
Diagnostics and Troubleshooting 3-61 Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action SCSI Port x Drive ID x has
3-62 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-19 ADU Diagnostic Messages continued Message Description Recommended Action Warning
Diagnostics and Troubleshooting 3-63 Integrated Management Log (IML) The Compaq Integrated Management Log (IML) replaces the Critical Error Log and C
3-64 Compaq ProLiant ML350 Maintenance and Service Guide Viewing the Event List 1. From Compaq Insight Manager, select the appropriate server, then s
1-4 Compaq ProLiant ML350 Maintenance and Service Guide System Components Exploded View 11131417161518203021122223332410 Figure 1-2. System compon
Diagnostics and Troubleshooting 3-65 Event List The Event List displays the affected components and the associated error messages. Though the same ba
3-66 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-20 Event Messages continued Event Type Event Message Action Processor Correctable
Diagnostics and Troubleshooting 3-67 Table 3-20 Event Messages continued Event Type Event Message Action Automatic Server Recovery System Lockup A
3-68 Compaq ProLiant ML350 Maintenance and Service Guide Rapid Error Recovery Compaq servers provide rapid recovery services for diagnosing and recov
Diagnostics and Troubleshooting 3-69 Table 3-21 ASR Features Feature Definition Software error recovery If enabled, ASR is activated if the OS hang
3-70 Compaq ProLiant ML350 Maintenance and Service Guide Compaq Server Management Driver The Compaq Server Management Driver resets the ASR timer con
Diagnostics and Troubleshooting 3-71 ASR Integrated Management Log (IML) Messages The Integrated Management Log (IML) records memory errors, as well
3-72 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-22 ASR IML Messages continued Message Description NMI – Fail-Safe Timer Expiration S
Diagnostics and Troubleshooting 3-73 Storage Fault Recovery Tracking This feature tracks over 12 failure-indication parameters, such as timeouts, spi
3-74 Compaq ProLiant ML350 Maintenance and Service Guide ROMPaq Error Recovery Options From time to time it may be desirable to upgrade the current s
Illustrated Parts Catalog 1-5 System Components Spare Parts List Table 1-2 System Components Spare Parts List Item Description Spare Part Number
Diagnostics and Troubleshooting 3-75 4. Insert the ROMPaq diskette. Although you use a normal ROMPaq diskette, this situation does not allow you to s
3-76 Compaq ProLiant ML350 Maintenance and Service Guide Compaq Insight Manager Compaq Insight Manager is the Compaq application for easily managing
Diagnostics and Troubleshooting 3-77 SNMP standards—allow integration with other management products. Flexible network conductivity—supports mu
Chapter 4 Connectors, Switches, and LED Indicators This chapter contains locations and descriptions of the following ProLiant ML350 server componen
4-2 Compaq ProLiant ML350 Maintenance and Service Guide System Board Components 1 2 3 4 5 678910111213141516171819202122232425262728 Figure 4-1. S
Connectors, Switches, and LED Indicators 4-3 Rear Panel Components 123456789 Figure 4-2. Rear panel components Table 4-2 Rear Panel Components It
4-4 Compaq ProLiant ML350 Maintenance and Service Guide Server Feature Board Components 12345 Figure 4-3. Server Feature Board components Table 4
Connectors, Switches, and LED Indicators 4-5 Switches This section contains graphics and tables showing switch locations on the ProLiant ML350 serv
4-6 Compaq ProLiant ML350 Maintenance and Service Guide 1on2 3 4 5 6 7 8 Figure 4-5. Server Feature Board configuration switchbank location and de
Connectors, Switches, and LED Indicators 4-7 LED (Status) Indicators This section contains graphics information for the following ProLiant ML350 se
1-6 Compaq ProLiant ML350 Maintenance and Service Guide Table 1-2 System Components Spare Parts List continued Item Description Spare Part Number
4-8 Compaq ProLiant ML350 Maintenance and Service Guide Power and Hard Drive Activity Indicators 21 Figure 4-6. Power and hard drive activity
Connectors, Switches, and LED Indicators 4-9 Integrated Network Controller Status Indicators 1 2 3 Figure 4-7. Integrated Network Controller statu
4-10 Compaq ProLiant ML350 Maintenance and Service Guide Auxiliary Power Indicator 1 Figure 4-8. Auxiliary power indicator location CAUTION: If
Chapter 5 Physical and Operating Specifications This chapter provides specifications for the Compaq ProLiant ML350 server. The following specificat
5-2 Compaq ProLiant ML350 Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height 44.45 cm/46.99 cm wit
Physical and Operating Specifications 5-3 Memory Table 5-2 ECC SDRAM Specifications Size 64-, 128-, 256-, and 512-MB Speed PC 133-MHz Type Regis
5-4 Compaq ProLiant ML350 Maintenance and Service Guide IDE CD-ROM Drive Table 5-4 IDE CD-ROM Specifications Applicable disk CD-ROM (modes 1 and
Physical and Operating Specifications 5-5 Table 5-4 IDE CD-ROM Specifications continued Laser parameters Type Semiconductor Laser GaA1As Wave le
5-6 Compaq ProLiant ML350 Maintenance and Service Guide Wide Ultra2 SCSI Hard Drives Table 5-5 Non-Hot-Plug Wide Ultra2 SCSI Hard Drives 18.2-GB
Physical and Operating Specifications 5-7 Table 5-6 Hot-Plug Wide Ultra2 SCSI Hard Drives 18.2-GB 18.2-GB 10-K 9.1-GB 9.1-GB 10-K Capacity 18
Chapter 2 Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for the ProLiant ML35
5-8 Compaq ProLiant ML350 Maintenance and Service Guide Compaq NC3163 Fast Ethernet Embedded NIC Table 5-7 Compaq NC3163 Fast Ethernet Embedded NI
Index A access panel part number 1-3 removing 2-7 removing, illustrated 2-7 replacing 2-7 access times CD-ROM drive 5-4 diskette drive
2 Compaq ProLiant ML350 Maintenance and Service Guide C cable routing diagrams CD-ROM drive 2-9 diskette drive 2-9 four-device SCSI cable 2-1
Index 3 locating 2-1, 3-2 overview 3-2 running 3-39 test error codes CD-ROM drive 3-50 diskette drive 3-44 hard drive 3-47, 3-50 keyboar
4 Compaq ProLiant ML350 Maintenance and Service Guide error codes See also test error codes 100 through 199 3-40 1100 through 1199 3-45 1200
Index 5 event type ASR system lockup 3-67 fan failure 3-65 machine environment fans 3-65 overheat condition 3-65 main memory Correctable Err
6 Compaq ProLiant ML350 Maintenance and Service Guide H hard drive hot-plug removing 2-20 removing, illustrated 2-20 replacing 2-20 non-hot-p
Index 7 rear panel components 4-3 removable media bays 2-22 removable media blank, removing 2-8 removable media device cables, removing 2-23
8 Compaq ProLiant ML350 Maintenance and Service Guide removing DIMMs, illustrated 2-29 replacing 2-29 size 5-3 specifications 5-3 speed 5
Index 9 PCI Hot Plug POST messages 3-20 PCI retainer, part number 1-6 PCI slots powered down, error message 3-20 Pentium III Processor See p
2-2 Compaq ProLiant ML350 Maintenance and Service Guide Electrostatic Discharge Information A discharge of static electricity can damage static-sen
10 Compaq ProLiant ML350 Maintenance and Service Guide processor configuration invalid 3-10 locations, illustrated 2-31 missing or terminator b
Index 11 security, ASR 3-70 serial port address conflict detected 3-18 identified 4-3 POST messages 3-18 test error codes 3-45 Server Feat
12 Compaq ProLiant ML350 Maintenance and Service Guide hard drives capacity 5-6, 5-7 data transfer rate 5-6, 5-7 height 5-7 interface type
Index 13 Modem Communications Test Error Codes 3-46 Non-Hot Plug Wide Ultra2 SCSI Hard Drives 5-6 Parallel Printer Test Error Codes 3-42 Point
14 Compaq ProLiant ML350 Maintenance and Service Guide utilities ADU accessing 3-5 description 3-3 diagnostic messages 3-53 locating 2-1 st
Removal and Replacement Procedures 2-3 This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the po
2-4 Compaq ProLiant ML350 Maintenance and Service Guide Preparation Procedures WARNING: Only authorized technicians trained by Compaq should att
Removal and Replacement Procedures 2-5 Server Warnings and Precautions WARNING: To reduce the risk of personal injury from hot surfaces, allow t
Notice © 2002 Compaq Information Technologies Group, L.P. Compaq, the Compaq logo, Compaq Insight Manager, ProLiant, ROMPaq, SmartStart, Netelligent,
2-6 Compaq ProLiant ML350 Maintenance and Service Guide Front Bezel Door CAUTION: Before removing the front bezel door, make sure that the serve
Removal and Replacement Procedures 2-7 Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system
2-8 Compaq ProLiant ML350 Maintenance and Service Guide Removable Media Blank NOTE: The removable media blank must be removed from an available r
Removal and Replacement Procedures 2-9 Cable Routing Diagrams 1 Figure 2-4. 1.44-MB diskette drive cable (1) 1 Figure 2-5. IDE CD-ROM drive cable
2-10 Compaq ProLiant ML350 Maintenance and Service Guide 12 Figure 2-6. Four-device SCSI cable (1) and power cable (2)1 Figure 2-7. Server Manage
Removal and Replacement Procedures 2-11 System Fan Module 1 Figure 2-8. System fan module location Table 2-1 System Fan Location Item Description
2-12 Compaq ProLiant ML350 Maintenance and Service Guide To remove the system fan module: 1. Complete the preparation procedures. See “Preparation
Removal and Replacement Procedures 2-13 4. Loosen the thumbscrew (2) securing the fan module to the chassis. 5. Rotate the fan module (3) countercl
2-14 Compaq ProLiant ML350 Maintenance and Service Guide Drive Bay Configuration The ProLiant ML350 server supports a maximum of eight internal dri
Removal and Replacement Procedures 2-15 Non-Hot-Plug Hard Drive To remove the non-hot-plug hard drive: 1. Complete the preparation procedures. See
Contents About This Guide Symbols in Text...v
2-16 Compaq ProLiant ML350 Maintenance and Service Guide 5. For systems equipped with a drive bay cover, loosen the thumbscrews (1), then remove th
Removal and Replacement Procedures 2-17 7. With a Torx T-15 screwdriver, remove the guide screws from the hard drive. Figure 2-15. Removing guide
2-18 Compaq ProLiant ML350 Maintenance and Service Guide Non-Hot-Plug Hard Drive Cage To remove a non-hot-plug hard drive cage: 1. Complete the pre
Removal and Replacement Procedures 2-19 7. With a Torx T-15 screwdriver, remove the four screws (1) securing the drive cage to the chassis. 8. Slid
2-20 Compaq ProLiant ML350 Maintenance and Service Guide Hot-Plug Hard Drive or Drive Blank The ProLiant ML350 server is optionally available with
Removal and Replacement Procedures 2-21 Hot-Plug Hard Drive Cage To remove the hot-plug hard drive cage: 1. Complete the preparation procedures. Se
2-22 Compaq ProLiant ML350 Maintenance and Service Guide Removable Media Devices and Mass Storage Devices The ProLiant ML350 server ships standard
Removal and Replacement Procedures 2-23 To remove a removable media device: 1. Complete the preparation procedures. See “Preparation Procedures” ea
2-24 Compaq ProLiant ML350 Maintenance and Service Guide 5. While pushing up the drivelock (1), pull the device (2) out of the drive bay. 12 Figure
Removal and Replacement Procedures 2-25 Expansion Slots 1234567 Figure 2-23. Locating the expansion slots Table 2-4 Expansion Slots Item Slot 1
iv Compaq ProLiant ML350 Maintenance and Service Guide Removal and Replacement Procedures continued System Board ...
2-26 Compaq ProLiant ML350 Maintenance and Service Guide Expansion Board (Server Feature Board) To remove an expansion board (Server Feature Board)
Removal and Replacement Procedures 2-27 5. Push in the expansion board slot release lever (1) to release it, then rotate the lever (2) outward. 6.
2-28 Compaq ProLiant ML350 Maintenance and Service Guide Memory The ProLiant ML350 server supports PC 133-MHz ECC SDRAM Dual Inline Memory Modules
Removal and Replacement Procedures 2-29 Memory Module To remove an SDRAM DIMM: 1. Complete the preparation procedures. See “Preparation Procedures”
2-30 Compaq ProLiant ML350 Maintenance and Service Guide Memory Combinations The following guidelines MUST be followed when installing or replacing
Removal and Replacement Procedures 2-31 Processor 4 1 23 Figure 2-28. Processor and Processor Power Module (PPM) slot locations Table 2-6 Process
2-32 Compaq ProLiant ML350 Maintenance and Service Guide To remove a processor: 1. Complete the preparation procedures. See “Preparation Procedures
Removal and Replacement Procedures 2-33 Processor Terminator Module A processor terminator module must be installed in each empty processor slot. T
2-34 Compaq ProLiant ML350 Maintenance and Service Guide Processor Power Module (PPM) Each Intel Pentium III processor supplied by Compaq comes wit
Removal and Replacement Procedures 2-35 System Board To remove the system board: 1. Complete the preparation procedures. See “Preparation Procedure
Contents v Chapter 4 Connectors, Switches, and LED Indicators Connectors...
2-36 Compaq ProLiant ML350 Maintenance and Service Guide 6. With a Torx T-15 screwdriver, remove the four screws (1) securing the system board to t
Removal and Replacement Procedures 2-37 Batteries The ProLiant ML350 server has a battery on the system board and a battery on the Server Feature B
2-38 Compaq ProLiant ML350 Maintenance and Service Guide Replacing the System Board Battery To remove and replace a lithium battery on the system b
Removal and Replacement Procedures 2-39 Replacing the Server Feature Board Battery To remove and replace a lithium battery on the system board: 1.
2-40 Compaq ProLiant ML350 Maintenance and Service Guide Power Supply To remove the power supply: 1. Complete the preparation procedures. See “Prep
Removal and Replacement Procedures 2-41 Feet To remove the feet from the chassis, one at a time: 1. Complete the preparation procedures. See “Prepa
Chapter 3 Diagnostics and Troubleshooting This chapter describes software and firmware diagnostic tools available for Compaq server products utilizing
3-2 Compaq ProLiant ML350 Maintenance and Service Guide Diagnostic Tools Utility Overview These tools were developed to assist in diagnosing problems
Diagnostics and Troubleshooting 3-3 Table 3-1 Diagnostic Tools continued Tool What it is How to run it Array Diagnostics Utility (ADU) A Windows-b
3-4 Compaq ProLiant ML350 Maintenance and Service Guide Default Configuration When the system is first powered up, the system ROM detects the unconfi
About This Guide This maintenance and service guide is a troubleshooting guide that can be used for reference when servicing the Compaq ProLiant™ M
Diagnostics and Troubleshooting 3-5 Utilities Access The SmartStart and Support Software CD contains the SmartStart program and many of the Compaq ut
3-6 Compaq ProLiant ML350 Maintenance and Service Guide Power-On Self-Test (POST) Error Messages The Power-On Self-Test (POST) is a series of diagnos
Diagnostics and Troubleshooting 3-7 Table 3-2 POST Error Messages Error Code Audible Beeps Probable Source of Problem Action A Correctable Memory
3-8 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem
Diagnostics and Troubleshooting 3-9 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action (Run System
3-10 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-11 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 207-Invalid
3-12 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-13 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 301-Keyboar
3-14 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
viii Compaq ProLiant ML350 Maintenance and Service Guide Compaq Technician Notes WARNING: Only authorized technicians trained by Compaq should a
Diagnostics and Troubleshooting 3-15 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 611-Primary
3-16 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-17 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 805-The boo
3-18 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-19 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1611-CPU Fa
3-20 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-21 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1620-Locked
3-22 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-23 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1724-Slot X
3-24 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
About This Guide ix Where to Go for Additional Help In addition to this guide, the following information sources are available: User documentati
Diagnostics and Troubleshooting 3-25 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1752-Slot X
3-26 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-27 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1771-Primar
3-28 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-29 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1777-Slot X
3-30 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-31 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1782-Disk C
3-32 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-33 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1786-Slot 1
3-34 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Chapter 1 Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts lists for the Compaq ProLiant™ ML350 serv
Diagnostics and Troubleshooting 3-35 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1789-Slot X
3-36 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-37 Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Problem Action 1796-Drive
3-38 Compaq ProLiant ML350 Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps Probable Source of Proble
Diagnostics and Troubleshooting 3-39 Diagnostics Software The Test Error Codes tables include all test error codes generated by Compaq products. Each
3-40 Compaq ProLiant ML350 Maintenance and Service Guide 100 – 199, Primary Processor Test Error Codes The 100 series of diagnostic error codes ident
Diagnostics and Troubleshooting 3-41 200 – 299, Memory Test Error Codes The 200 series of diagnostic error codes identifies failures with the memory
3-42 Compaq ProLiant ML350 Maintenance and Service Guide 300 – 399, Keyboard Test Error Codes The 300 series of diagnostic error codes identifies fai
Diagnostics and Troubleshooting 3-43 500 – 599, Video Display Unit Test Error Codes The 500 series of diagnostic error codes identifies failures with
3-44 Compaq ProLiant ML350 Maintenance and Service Guide 600 – 699, Diskette Drive Test Error Codes The 600 series of diagnostic error codes identifi
Commentaires sur ces manuels