4-12 Compaq ProLiant 8500 Server Maintenance and Service Guide
Power Supply LED Indicators
Figure 4-10 and Table 4-11 show the location and a description of both power supply
LED indicators.
3
4
1
2
Figure 4-10. Compaq ProLiant 8500 server power supply LEDs
Table 4-11
Power Supply Positioning and Indicators
Item Component Condition Meaning
Power supply 1
Power supply 2
Status indicators Green Normal operation
Green/amber alternating Power supply failed to restart after a
prolonged fault.
Green flashing Power supply will restart within
20 seconds.
Amber Fault detected in this power supply or
system.
Amber flashing Failed self-test.
Off System is in standby mode or
interlocks are disabled.
AC power indicators Green AC power is connected to this power
supply.
Off No AC power is connected to this
supply.