HP StorageWorks
Command View XP installation guide
Part number: B9357–96115
First edition: March 2005
Vue de la page 0
1 2 3 4 5 6 ... 57 58

Résumé du contenu

Page 1 - HP StorageWorks

HP StorageWorksCommand View XP installation guidePart number: B9357–96115First edition: March 2005

Page 2

10 About this guide

Page 3 - Contents

Command View XP installation guide 111 InstallationHP StorageWorks Command View XP is a disk array management platform for HP StorageWorks XP48/XP512/

Page 4 - 4Contents

12 InstallationVerifying system requirementsNOTE: Refer to the readme.txt file on the Command View CD for the most current requirements and any last-m

Page 5

Command View XP installation guide 13Verify Web client requirementsThe Web client is any computer used to access Command View through a Web browser. M

Page 6 - 6Contents

14 InstallationNOTE: If you install an earlier version of the JRE after installing the supported version, do not set the client browser to use the old

Page 7 - About this guide

Command View XP installation guide 15On UNIX systems, the tmp directory is used during the Path Connectivity host agent deployment process. If your tm

Page 8

16 InstallationWindows 2000 LP8000 (HP 176479-B21)LP952L5-4.82a4 (SNIA 1.8),5-5.00a10-1 (SNIA 1.12.2.0),5-2.13a4 (SNIA1.8),5-2.20a12-2 (SNIA 1.12.2.0)

Page 9 - HP technical support

Command View XP installation guide 17Red Hat Linux Advanced Server 2.1/Red Hat Enterprise Linux 3.0LP9002 (2 GB)LP9000LP8000LP952 (2 GB)4.20p (SNIA 1.

Page 10 - 10 About this guide

18 InstallationVerify Command Line Interface (CLI) requirementsIf you are installing the Command View Command Line Interface (CLI) and/or Path Connect

Page 11 - 1 Installation

Command View XP installation guide 19Installing Command ViewPrepare for upgradeIf you are upgrading from a previous version of Command View XP, consid

Page 12 - Verifying system requirements

Legal and notice information© Copyright 1999–2005 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with

Page 13

20 InstallationNOTE: For the XP128/XP1024/XP12000, Command View array management web clients communicate directly with the array. Therefore, access th

Page 14

Command View XP installation guide 21Alternate firewall case 2: Firewall running on SVPAssuming that all SVP outbound traffic is unrestricted by the S

Page 15

22 InstallationConfirming or modifying the system name1. From the Control Panel in Windows, click System.2. Depending on your version of Windows, clic

Page 16

Command View XP installation guide 23Uninstall Command View XPIf you have a previous version of Command View XP installed, you must uninstall it prior

Page 17

24 Installationc. Click Next.d. Select the operating systems that your hosts are running in the Choose Host Agent Platforms window, and click Next.e.

Page 18

Command View XP installation guide 25Verify Command View execution1. Start a Web browser.2. Enter the IP address of the Command View management statio

Page 19 - Installing Command View

26 InstallationAfter installation, SMI-S XP, by default, starts in the SSL mode. If the client application does not support SSL communication with the

Page 20

Command View XP installation guide 27NOTE: Do not modify any parameter that is not listed in Table 11.The UserAccountsManager.bat fileUser accounts ar

Page 21 - Verify the host system name

28 InstallationNOTE: The -LG is the only input parameter that you can use to list the available groups and users. Currently, the available groups are

Page 22 - Verify the SNMP configuration

Command View XP installation guide 29• Manual: If the service is enabled to start manually, the service starts when the Command View services are star

Page 23 - Modify or repair Command View

Command View XP installation guide 3About this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Intend

Page 24 - Verify Command View services

30 Installation1. Import the server certificate into the client trust store.a. Copy the server certificate to the client system.b. Execute the followi

Page 25 - Set Up SMI-S XP

Command View XP installation guide 31Set up event notification and history reportingTo set up event notification and reporting, use the instructions l

Page 26 - Configuring SMI-S XP

32 InstallationDisable the Web Proxy serviceWhen you are using a Web browser to manage an XP128/XP1024/XP12000, disable the Web proxy on the client by

Page 27 - Listing groups and users

Command View XP installation guide 33• Use Java 2 v1.4.2 for <applet> (requires restart)Figure 2 Internet Options (Internet Explorer)3. Click OK

Page 28 - Viewing help files

34 InstallationCertain users may find they need the flexibility of the ALWAYS setting, which ensures that Command View always determines the timeout v

Page 29 - Enabling SSL

Command View XP installation guide 353. Click Licensing in the left panel in Command View.4. Click the disk array you want to access from the Serial N

Page 30 - Uninstalling SMI-S XP

36 InstallationPath Connectivity is installed as part of the Command View installation, and it is required to manage an XP disk array with Command Vie

Page 31 - Setting up Command View

Command View XP installation guide 37Although these switches are supported, Path Connectivity does not automatically detect them in your SAN. Use the

Page 32 - Disable the Web Proxy service

38 Installation• Only one remote deployment tool may run at a given time.• Review the online Host Software Installation checklist. To view the checkli

Page 33

Command View XP installation guide 39•Enter rpm -Uvh /mnt/cdrom/RedHat/RPMS/rsh-ser*. You may need to mount your CD-ROM if the OS cannot find the dire

Page 34 - Install license keys

4ContentsEnabling the SMI-S CIMOM service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Disabling SMI-S CI

Page 35 - Setting up Path Connectivity

40 Installation2. Click Add Multiple Hosts. A dialog box displays a table.3. In the table, enter the host name or IP address, admin user name, and pas

Page 36

Command View XP installation guide 41Installing host agents using the local methodDownloading the host agent file1. Access Command View from your work

Page 37 - Prerequisites

42 Installation4. Run the uninstall script by entering: unix_local_uninstall.sh.Add or remove host agent installation filesIf you have already install

Page 38 - 38 Installation

Command View XP installation guide 43Integrating Command View with other platformsIntegrating with HP OpenView Storage Area ManagerCommand View and St

Page 39 - Designating multiple hosts

44 InstallationIntegration can occur at the following levels:• Graphical User Interface (GUI)• Command Line Interface (CLI)• Message or “event” notifi

Page 40 - Installing the host agents

Command View XP installation guide 452TroubleshootingThis chapter contains troubleshooting information about installing, configuring, and logging on t

Page 41

46 TroubleshootingThe browser displays the message, “Invalid user name or password,” but never displays a login box.Your session authorization may hav

Page 42 - 42 Installation

Command View XP installation guide 47General Command View connection errorsTable 16 General connection errorsSymptom Cause/SolutionYour browser crashe

Page 43

48 TroubleshootingError Message: “A connection error occurred between the Remote Control and the controller.(Control: {Array #} )”(XP48/XP512 only)If

Page 44 - Event notification

Command View XP installation guide 49Host agent deployment errorsTable 17 Host agent deployment errorsSymptom Cause/SolutionThe host agent does not de

Page 45 - 2Troubleshooting

Command View XP installation guide 5Integrating with miscellaneous management applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46 - Symptom Cause/Solution

50 TroubleshootingHost agent uninstallation errorsYou are not able to reload the Emulex driver for the Linux host after installing the host agent.When

Page 47

Command View XP installation guide 51A Installation checklistThis appendix contains a helpful installation checklist that you can print out and refere

Page 48 - (XP48/XP512 only)

52 Installation checklistSetting up Command View• If you are moving from an existing management station to a new management station, use the Backup Ut

Page 49 - Host agent deployment errors

Command View XP installation guide 53IndexAaddingdisk arrays 34host agent installation files 42switches 36Apache Web Server 22audience 7authorized res

Page 50

54 IndexUuninstallingCommand View 24VverifyingCommand View execution 25Command View services 24disk array firmware levels 14SNMP 22Wwarningrack stabil

Page 51 - A Installation checklist

Figures1 Example of a network with added security from a firewall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Internet Opti

Page 53

Tables1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Page 55

6Contents

Page 56

Command View XP installation guide 7About this guideThis guide provides information about:• Installing Command View XP, Path Connectivity, SMI-S XP, a

Page 57

8 About this guideDocument conventions and symbolsCAUTION: Indicates that failure to follow directions could result in damage to equipment or data.IMP

Page 58

Command View XP installation guide 9HP technical supportTelephone numbers for worldwide technical support are listed on the HP web site: http://www.hp