Vue de la page 57
Operation and Management
58 MSA1000 Reference Guide
To replace a drive:
1. Verify the Activity LED indicator is OFF.
Hard Drive LEDs are illustrated in Figure 14.
2. Press the ejector 1 and pivot the lever 2 to full open position.
3. Pull the drive partially out of the bay and allow time for the disk to stop
rotating.
4. Pull the drive completely out of the storage system drive bay 3.
Figure 22: Opening the drive tray latches
5. On the new hard drive, press the ejector and pivot the lever to a full open
position.
2
3
1