Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Guide de l'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 112
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
3-4 RAID Array 3000 Pedestal Storage Subsystem Hardware Users Guide
Compaq Confidential Need to Know Required
Writer: Bob Young Project: RAID Array 3000 Pedestal Storage Subsystem Hardware Users Guide Comments:
Part Number: EK-SMCPO-UG. C01 File Name: d-ch3 Maintenance.doc Last Saved On: 12/4/00 1:50 PM
Table 3-1
Disk Drive SBB Status LEDs
Activity LED Fault LED Indication
On Off Drive is operating properly.
Off Off Drive is inactive and operating normally. There is no fault.
On On
Fault status: drive is defective. Recommend that you
replace the device.
Off On
Fault status: drive is inactive and not spinning.
Recommend that you replace the device.
On Flashing
Fault status: drive is active and slowing down due to the
fault.
Figure 3-2. Disk drive status LEDs
Controller LEDs
The LEDs on the front panel of the controller monitor host and disk channel
activity and a controller fault condition. The reset button/LED flashes green
approximately once every second (heartbeat) to indicate that the controller is
operating normally. See Chapter 2 Raid Array Controller for more
information.