ProLiant 3000 Servers
For Use With Intel 350 MHz or Greater Processor-Based Servers Only
Maintenance and Service Guide
First Edition (February 1999)
Part Number 113803-001
Spare Part Number 114651-001
Compaq Computer Corporation
Vue de la page 0
1 2 3 4 5 6 ... 161 162

Résumé du contenu

Page 1 - ProLiant 3000 Servers

ProLiant 3000 ServersFor Use With Intel 350 MHz or Greater Processor-Based Servers OnlyMaintenance and Service GuideFirst Edition (February 1999)Part

Page 2

1-2 Illustrated Parts CatalogSystem Components Exploded View121026131219151914433523171620224440Figure 1-2. Exploded view of Compaq ProLiant 3000 S

Page 3 - Contents

3-43Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD Diagnostic Mes

Page 4 - Chapter 3

3-44 Diagnostic ToolsDAAD Diagnostic Messages Continued Message Description Recommended ActionLogical Drive Xstatus = WRONGDRIVE REPLACEDA physic

Page 5

3-45Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD Diagnostic Mes

Page 6 - About This Guide

3-46 Diagnostic ToolsIntegrated Management LogOn servers supporting the Integrated Management Display, the Compaq Integrated ManagementLog (IML) re

Page 7 - Integrated Management Display

3-47Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideViewing the Event L

Page 8 - Telephone Numbers

3-48 Diagnostic ToolsEvent ListThe event list displays the affected components and the associated error messages. Though thesame basic information

Page 9 - Illustrated Parts Catalog

3-49Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideEvent Messages Cont

Page 10

3-50 Diagnostic ToolsRapid Recovery ServicesCompaq servers provide rapid recovery services for diagnosing and recovering from errors.These tools ar

Page 11 - Spare Parts List

3-51Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideThe available recov

Page 12

3-52 Diagnostic Tools Hardware Requirements To use this level of ASR-2 over a modem, you need the following: Compaq modem or optional Hayes comp

Page 13

1-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSpare Parts ListTabl

Page 14 - Chapter 2

3-53Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Compaq Integrated

Page 15 - Preparation Procedures

3-54 Diagnostic Tools The following ASR-2 flow chart shows you the sequence of events after a hardware or softwareerror occurs: Hardware/Software

Page 16 - Rack Warnings

3-55Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Booting into Compa

Page 17

3-56 Diagnostic Tools Table 3-23Compaq System Configuration Utility Pager Settingsfor Booting into Compaq Utilities Pager Data Setting Descrip

Page 18 - Locking Casters

3-57Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Compaq System Conf

Page 19 - Caster Mounting Support

3-58 Diagnostic Tools Compaq System Configuration Utility Pager Settingsfor Booting into Compaq Utilities Continued Pager Data Setting Descri

Page 20 - Front Bezel Door

3-59Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Network controll

Page 21 - Front Fixed Bezel

3-60 Diagnostic Tools Critical Error Log The Critical Error Log records memory errors, as well as catastrophic hardware and softwareerrors that cau

Page 22 - Rack-Mount Bezel

3-61Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Critical Error Log

Page 23 - Top Access Panel

3-62 Diagnostic Tools Revision History Table Some errors can be resolved by reviewing changes to the server configuration. The server has anAutomat

Page 24 - U-Channel Access Panel

1-4 Illustrated Parts CatalogSpare Parts List Continued Ref Description Spare Part #MASS STORAGE DEVICES22 32x IDE CD-ROM Drive with Tray 328707-

Page 25 - Side Access Panel

3-63Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Storage Fault Reco

Page 26

3-64 Diagnostic Tools Remote Service Features Compaq servers have the following management features that you can access via modem ornetwork: Table

Page 27

3-65Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide ROMPaq Using flash

Page 28 - Figure 2-11. Location of fans

3-66 Diagnostic Tools Asset Management - Exports asset information from the Compaq Insight Managerdatabase to leading database and spreadsheet ap

Page 29 - Front Fan(s)

4-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 4Connectors,

Page 30 - Fan Baffle

4-2 Connectors, Switches, Jumpers, and LEDsSystem I/O Board ConnectorsFigure 4-2 shows the system I/O board connectors for ProLiant 3000 Servers. T

Page 31 - Rear Fan

4-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSwitchesThis section

Page 32 - Description of Drive Bays

4-4 Connectors, Switches, Jumpers, and LEDsProcessor Switch SettingsThe following figures and table show the location and default settings of the p

Page 33 - Drive Cage Assemblies

4-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide1on2450 MHz3456Figur

Page 34 - Duplex Enabler Board

4-6 Connectors, Switches, Jumpers, and LEDsJumpersThe external battery jumper for ProLiant 3000 Servers is located on the system I/O board.Figure 4

Page 35 - Ultra2 Hot-Plug Drive Cage

1-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSpare Parts List C

Page 36 - Hard Drives

4-7Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideLEDsThis section con

Page 37 - Ultra2 Hot-Plug Hard Drives

4-8 Connectors, Switches, Jumpers, and LEDsPower Switch LEDThe power switch LED is located on the front of the server beneath the power switch andi

Page 38 - Removable Media Devices

4-9Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDiskette DriveThe di

Page 39 - Removable Media Drives

4-10 Connectors, Switches, Jumpers, and LEDsHot-Plug Hard Drive LEDsLEDs on each hot-plug hard drive show the operational status of the hard drive.

Page 40

4-11Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDrive IndicatorsOnl

Page 41

5-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 5Physical an

Page 42

5-2 Physical and Operating SpecificationsSystem UnitTable 5-1System Unit SpecificationsU.S. MetricDimensionsHeight 20.5 in 52.1 cmDepth 24.5 in 62.

Page 43 - SOCKET 8

5-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuidePower SupplyTable 5-

Page 44 - Table 2-2

5-4 Physical and Operating SpecificationsSDRAM Dual Inline Memory ModulesCAUTION: Use only SDRAM DIMMs of the same size, speed, and manufacturer.

Page 45

5-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide1.44-MB Diskette Dri

Page 46

2-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 2Removal and

Page 47

5-6 Physical and Operating SpecificationsIDE CD-ROM DriveTable 5-5IDE CD-ROM Drive SpecificationsU.S. MetricDimensionsHeight 1.7 in 42.9 mmWeight 5

Page 48 - Processor

5-7Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideIDE CD-ROM Drive Spe

Page 49 - Processor Power Module

5-8 Physical and Operating SpecificationsSmart Array 3200 ControllerTable 5-6Smart Array 3200 Controller SpecificationsU.S. MetricDimensionsHeight

Page 50 - Hot-Plug Power Supply

5-9Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideHot-Plug Wide-Ultra

Page 51

5-10 Physical and Operating SpecificationsHot-Plug Wide-Ultra2 Hard DrivesTable 5-8Hot-Plug Wide-Ultra2 Hard Drive Specifications4.3 GB 4.3 GB 9.1

Page 52 - Power Supply Blank Panel

5-11Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideNon-Hot-Plug Wide U

Page 53 - Power Backplane Board

5-12 Physical and Operating SpecificationsHot-Plug Wide-Ultra SCSI-3 Hard DrivesTable 5-10Hot-Plug Wide-Ultra SCSI-3 Hard Drive Specifications4.3 G

Page 54 - System I/O Board with Subpan

Index-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide IndexAAC power

Page 55 - Power Switch

Index-2cables ContinuedSCSI removable media, folding and routing2-29Wide SCSI w/Terminator, part number 1-4card guide, part number 1-4carton, pa

Page 56 - External Replacement Battery

Index-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD (Drive Arra

Page 57

2-2 Removal and Replacement ProceduresSymbols in EquipmentWARNING: Any surface or area of the equipment marked with thesesymbols indicates the pr

Page 58 - Diagnostic Tools

Index-4Eelectrostatic discharge, preventing 2-1Enabler boardDuplex, removing 2-21Duplex, replacing 2-21Simplex, removing 2-21Simplex, replacin

Page 59 - Utilities Access

Index-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guideerror Continue

Page 60 - Running Compaq Utilities

Index-6error Continued505-XX, description 3-22506-XX, description 3-22507-XX, description 3-22508-XX, description 3-22509-XX, description

Page 61 - Power-On Self-Test (POST)

Index-7Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guideerror Continue

Page 62 - POST Error Messages

Index-8error ContinuedDrive Monitoring features are unobtainable,description 3-40Drive Monitoring is NOT enabled for drive bayX, description 3-4

Page 63 - 3-6 Diagnostic Tools

Index-9Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guidefansbaffle, part

Page 64

Index-10illustrations Continuedcaster mounting support, removing 2-6casters, removing 2-5CD-ROM drivecable folding and routing 2-28removing

Page 65 - 3-8 Diagnostic Tools

Index-11Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideIP/IPXsetting a

Page 66

Index-12panels Continuedside accesspart number 1-3removing 2-12removing, illustrated 2-12replacing 2-12top accesspart number 1-3removing

Page 67 - 3-10 Diagnostic Tools

Index-13Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guidepower backplane

Page 68

2-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideRack WarningsWARNING

Page 69 - 3-12 Diagnostic Tools

Index-14ROMPaqFirmware Upgrade Utility, accessing 3-2, 3-3ROM upgrade procedure 3-65SSCSIcable folding and routing, illustrated 2-29Duplex Hot-P

Page 70

Index-15Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guidesystems referen

Page 71 - 3-14 Diagnostic Tools

Index-16Wwarningsbattery handling and disposal 2-43CD-ROM drive 2-2component level repairs viiidefinition viielectrical shock vii, viii, 2-2

Page 72

2-4 Removal and Replacement ProceduresServer Warnings and PrecautionsWARNING: To reduce the risk of personal injury or damage to the server, youm

Page 73 - 3-16 Diagnostic Tools

2-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideLocking CastersTo re

Page 74 - Diagnostics Software

2-6 Removal and Replacement ProceduresCaster Mounting SupportTo remove the caster mounting support:1. Perform the preparation procedures. See “Pre

Page 75 - Running Diagnostics

NoticeThe information in this publication is subject to change without notice.COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OREDITORIA

Page 76 - Table 3-2

2-7Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideFront Bezel DoorTo r

Page 77 - Memory Test Error Codes

2-8 Removal and Replacement ProceduresFront Fixed BezelThe front fixed bezel must be removed to replace the power switch. To remove the frontfixed

Page 78 - Keyboard Test Error Codes

2-9Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideRack-Mount BezelThe

Page 79 - Table 3-6

2-10 Removal and Replacement ProceduresTop Access PanelWARNING: To reduce the risk of personal injury from hot surfaces, allow theinternal system

Page 80 - Table 3-8

2-11Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideU-Channel Access Pa

Page 81 - Serial Test Error Codes

2-12 Removal and Replacement ProceduresSide Access PanelWARNING: To reduce the risk of personal injury from hot surfaces, allow theinternal syste

Page 82 - Hard Drive Test Error Codes

2-13Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideIntegrated Manageme

Page 83 - Tape Drive Test Error Codes

2-14 Removal and Replacement Procedures7. Press the four latches on the rear of the IMD 3.8. Pull the IMD from the front of the server 4.COMPACT3

Page 84 - Table 3-13

2-15Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideFansCompaq ProLiant

Page 85 - 3-28 Diagnostic Tools

2-16 Removal and Replacement ProceduresFront Fan(s)The front fans are removed for replacement or to replace the Integrated Management Display,the f

Page 86 - Table 3-14

iiiCompaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideContentsAbout This G

Page 87 - Test Error Codes

2-17Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideFan BaffleThe fan b

Page 88 - Table 3-17

2-18 Removal and Replacement ProceduresRear FanRemove the rear fan for replacement or for upgrading to another model fan.To remove the rear fan:1.

Page 89 - Table 3-19

2-19Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideRemovable Media and

Page 90

2-20 Removal and Replacement ProceduresDrive Cage AssembliesProLiant 3000 Servers ship with either Wide-Ultra or Ultra2 drive cage assemblies. The

Page 91 - Table 3-20

2-21Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSimplex Enabler Boa

Page 92 - Starting DAAD

2-22 Removal and Replacement ProceduresUltra2 Hot-Plug Drive CageTo remove the Ultra2 hot-plug drive cage assembly:1. Perform the preparation proc

Page 93

2-23Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideHard DrivesWide-Ult

Page 94

2-24 Removal and Replacement ProceduresUltra2 Hot-Plug Hard DrivesCompaq ProLiant 3000 Servers may ship with Ultra2 hot-plug hard drives. Ultra2 ho

Page 95 - 3-38 Diagnostic Tools

2-25Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideRemovable Media Dev

Page 96

2-26 Removal and Replacement ProceduresRemovable Media DrivesThe removable media drives are removed for replacement or when installing anothermedia

Page 97 - 3-40 Diagnostic Tools

ivChapter 3Diagnostic ToolsDefault Configuration...

Page 98

2-27Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDiskette DriveThe d

Page 99 - 3-42 Diagnostic Tools

2-28 Removal and Replacement ProceduresCable Folding and Routing DiagramsFigure 2-24. CD-ROM drive cable folding and routing diagramFigure 2-25. Di

Page 100 - DAAD Diagnostic Messages

2-29Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideFigure 2-26. Array

Page 101 - 3-44 Diagnostic Tools

2-30 Removal and Replacement ProceduresMemoryCompaq ProLiant 3000 Servers ship standard with either 128 MB or 256 MB SynchronousDRAM (SDRAM) Dual I

Page 102

2-31Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideAny combination of

Page 103 - Integrated Management Log

2-32 Removal and Replacement ProceduresTo remove an SDRAM DIMM:1. Perform the preparation procedures. See “Preparation Procedures” earlier in this

Page 104 - Printing the Event List

2-33Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSmart Array 3200 Co

Page 105 - Event Messages

2-34 Removal and Replacement ProceduresNetelligent 10/100 TX UTP PCI ControllerThe Compaq Netelligent 10/100 TX UTP network controller is removed f

Page 106

2-35Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideProcessorCompaq Pro

Page 107 - Rapid Recovery Services

2-36 Removal and Replacement ProceduresProcessor Power ModuleTo remove a processor power module:1. Perform the preparation procedures. See “Prepar

Page 108 - Attended Recovery

vCompaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 4Connectors, S

Page 109 - Hardware Requirements

2-37Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideHot-Plug Power Supp

Page 110 - Compaq Health Driver

2-38 Removal and Replacement ProceduresNOTE: You do not need to remove power from the unit for a hot-plug power supply replacementin a redundant

Page 111 - 3-54 Diagnostic Tools

2-39Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuidePower Supply Blank

Page 112

2-40 Removal and Replacement ProceduresPower Backplane BoardThe power backplane board is removed for replacement.To remove the power backplane boar

Page 113 - Table 3-23

2-41Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSystem I/O Board wi

Page 114 - Continued

2-42 Removal and Replacement ProceduresPower SwitchIMPORTANT: To completely remove all power from the system, you must disconnect thepower cord f

Page 115 - 3-58 Diagnostic Tools

2-43Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideExternal Replacemen

Page 116 - Server Health Logs

2-44 Removal and Replacement Procedures3. Connect the battery cable to battery header E9 on the system board.4. Remove the adhesive backing from

Page 117 - Critical Error Log Messages

3-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 3Diagnostic

Page 118 - Critical Error Log Messages

3-2 Diagnostic Tools Default Configuration When the system is first powered on, the system ROM detects the un-configured state of thehardware and

Page 119 - Revision History Format

viiCompaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideAbout This GuideThis

Page 120

3-3Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Running Compaq Util

Page 121 - Remote Service Features

3-4 Diagnostic Tools Power-On Self-Test (POST) POST is a series of diagnostic tests that run automatically on Compaq computers when thesystem is tu

Page 122 - Compaq Insight Manager

3-5Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages

Page 123 - Compaq Insight Manager

3-6 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 124 - Chapter 4

3-7Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages

Page 125 - System I/O Board Connectors

3-8 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 126 - Switches

3-9Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Messages

Page 127 - Processor Switch Settings

3-10 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 128 - Table 4-4

3-11Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Message

Page 129

3-12 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 130 - Hot-Plug Power Supply LEDs

viii About This GuideWARNING: To reduce the risk of personal injury from electrical shock andhazardous energy levels, do not exceed the level of r

Page 131 - CD-ROM Drive LED

3-13Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Message

Page 132 - Diskette Drive

3-14 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 133 - Hot-Plug Hard Drive LEDs

3-15Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide POST Error Message

Page 134 - Indicators

3-16 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem Recommended Action

Page 135 - Chapter 5

3-17Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service Guide Diagnostics Softw

Page 136 - System Unit

3-18 Diagnostic Tools6. Disable the power-on password by using the Password Disable switch on the system board,if you do not have access to the pa

Page 137 - Power Supply

3-19Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuidePrimary Processor T

Page 138 - SDRAM DIMM Specifications

3-20 Diagnostic ToolsMemory Test Error CodesThe 200 series of Diagnostic error codes identifies failures with the memory subsystem.Table 3-3Memory

Page 139 - 1.44-MB Diskette Drive

3-21Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideKeyboard Test Error

Page 140 - IDE CD-ROM Drive

3-22 Diagnostic ToolsVideo Display Unit Test Error CodesThe 500 series of Diagnostic error codes identifies failures with video or system board fun

Page 141

ixCompaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideTelephone NumbersFor

Page 142 - Smart Array 3200 Controller

3-23Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDiskette Drive Test

Page 143 - Table 5-7

3-24 Diagnostic ToolsSerial Test Error CodesThe 1100 series of Diagnostic error codes identifies failures with serial/parallel interface boardor sy

Page 144 - Table 5-8

3-25Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideHard Drive Test Err

Page 145 - Table 5-9

3-26 Diagnostic ToolsTape Drive Test Error CodesThe 1900 series of Diagnostic error codes identifies failures with tape cartridges, tape drives,tap

Page 146 - Table 5-10

3-27Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideAdvanced VGA Board

Page 147

3-28 Diagnostic ToolsAdvanced VGA Board Test Error Codes Continued Error Code Description Recommended Action2419-xx2420-xx2421-xx2422-xx2423-xx

Page 148 - Continued

3-29Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideNetFlex-2 Controlle

Page 149 - Continued

3-30 Diagnostic ToolsCompaq Network Interface BoardsTest Error CodesThe 6000 series of Diagnostic error codes identifies failures with 32-bit DualS

Page 150

3-31Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideSCSI Hard Drive Tes

Page 151

3-32 Diagnostic ToolsSCSI Tape Drive Test Error CodesThe 6700 series of Diagnostic error codes identifies failures with tape cartridges, tape drive

Page 152

1-1Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideChapter 1Illustrated

Page 153

3-33Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideServer Manager/R Bo

Page 154

3-34 Diagnostic ToolsPointing Device Interface Test Error CodesThe 8600 Diagnostic error codes identifies failures with the pointing device (mouse,

Page 155

3-35Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideStarting DAADTo sta

Page 156

3-36 Diagnostic ToolsDAAD Diagnostic MessagesTable 3-21 lists DAAD diagnostic messages in alphabetical order.Table 3-21DAAD Diagnostic MessagesMess

Page 157 - Index-11

3-37Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD Diagnostic Mes

Page 158

3-38 Diagnostic ToolsDAAD Diagnostic Messages Continued Message Description Recommended ActionAcceleratorstatus: Cache wasautomaticallyconfigur

Page 159 - Index-13

3-39Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD Diagnostic Mes

Page 160

3-40 Diagnostic ToolsDAAD Diagnostic Messages Continued Message Description Recommended ActionController needsreplacing (DAADError 104)The Intell

Page 161 - Index-15

3-41Compaq ProLiant 3000 Servers, for use with Intel 350 MHz or greater processor-based servers only, Maintenance and Service GuideDAAD Diagnostic Mes

Page 162

3-42 Diagnostic ToolsDAAD Diagnostic Messages Continued Message Description Recommended ActionDrive (bay) X wasinadvertentlyreplacedThe physical

Commentaires sur ces manuels