Compaq ProLiant BL20p Guide d'installation Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 108
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
Server Error Messages
C-2 Compaq ProLiant BL20p Server Blade Setup and Installation Guide
COMPAQ CONFIDENTIAL
Writer: Christine Portillo File Name: g-appc Server Error Messages.doc
Codename: AvX Part Number: 307131-001 Last Saved On: 11/1/02 1:05 PM
Table C-1: POST Error Messages
Error Code Audible
Beeps
Probable Source
of Problem
Action
Critical Failure Detected - System
Shutting Down in
None Blower assembly has failed. Replace blower
assembly.
Processor in incorrect socket. -
System Halted!
None Processor is installed in
socket 2 only.
Install processor
in socket 1.
REDUNDANT ROM ERROR:
Backup ROM invalid. - Run
ROMPAQ to correct error condition
None System ROM and
redundant ROM are both
corrupt.
Run ROMPaq
Utility.
REDUNDANT ROM ERROR:
Bootblock invalid. - Contact
COMPAQ Representative
None ROM bootblock is corrupt. Contact
Compaq
authorized
service provider.
805-Unsupported Processor
Detected
System will ONLY boot ROMPAQ
Utility.
None One or both processors are
unsupported.
Install supported
processors.
Vue de la page 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 107 108

Commentaires sur ces manuels

Pas de commentaire