The HP ProLiant SL390s G7 server is part of a new family, HP ProLiant SL6500 Scalable System, of HP server solutions optimized for
scale-out customers to greatly reduce costs, maximize power efficiency, by sharing power supplies and fans, and maintain total
flexibility.
The SL390s G7 consists of three different server trays, each with their own benefits. The 1U half width tray is designed for compute
density, and the 2U and 4U half width trays are designed for GPU density, support is up to 3 GPUs in the 2U and 8 GPUs in the 4U
tray. They each use the same system board and go into the 4U HP ProLiant s6500 Chassis. The SL390s G7 is a two socket Intel server
with 12 DDR3 DIMM sockets, two 1 Gb Ethernet ports, one 10 Gb Ethernet port (SFP+) and an option on board Infiniband port
(QSFP).
The SL390s G7 1U half width server tray support a low profile x16 gen 2 PCI-e slot and two 3.5" or four 2.5" hard drives.
The SL390s G7 2U half width server trays support a low profile x8 gen2 PCI-e slot, while also supporting three internal x16 gen2 slots
dedicated for three GPU's (up to 225 watts each). The SL390s G7 4 U half width server tray support a low profile x8 gen2 PCI-e slot,
while also supporting eight internal x16 gen2 slots dedicated for eight GPU's (up to 225 watts each)
1U Open View:
1U Open View:1U Open View:
1U Open View:
1U Front View:
1U Front View:1U Front View:
1U Front View:
1.
Two 3.5" or four 2.5" non-hot plug hard drives using a quick
release drive carrier
1.
Low profile x16 PCI-e Gen 2
2.
12 DDR3 DIMM Slots
2.
Optional Infiniband port (QSFP)
3.
Support for up to two Intel® 5600 sequence processors
3.
1Gb Ethernet port
4.
iLO3 dedicated management port
5.
UID LED
6.
2 front USB ports
7.
1 Gb Ethernet port
8.
10Gb Ethernet port (SFP+)
9.
Power Button
10.
Serial port (RJ45)
11.
Video Port
QuickSpecs
HP ProLiant SL390s Generation 7 (G7)
HP ProLiant SL390s Generation 7 (G7)HP ProLiant SL390s Generation 7 (G7)
HP ProLiant SL390s Generation 7 (G7)
Overview
DA - 13713 Worldwide — Version 8 — February 14, 2011
Page 1
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - QuickSpecs

The HP ProLiant SL390s G7 server is part of a new family, HP ProLiant SL6500 Scalable System, of HP server solutions optimized forscale-out customers

Page 2

WarrantyWarrantyWarrantyWarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authori

Page 3

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Page 4

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Page 5

Service and SupportService and SupportService and SupportService and SupportFor increased uptime, productivity and ROI - HP Care Pack packaged service

Page 6

NOTE:NOTE:NOTE:NOTE: Care Pack Services availability may vary by product and country.Recommended HP Care Pack Services for optimal satisfaction with y

Page 7

http://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EEE ProLiant Servers Installation and Startup ServiceProLiant Servers Installation and Startup Servi

Page 8

Improved system uptimePredictable repair timesMore effective IT resource planningConsistent level of hardware support across your multi-technology sys

Page 9

Customer TechnicalCustomer TechnicalCustomer TechnicalCustomer TechnicalTrainingTrainingTrainingTrainingHP Services continues to be recognized for ser

Page 10

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Page 11

Optical DriveOptical DriveOptical DriveOptical DriveNone ship standardPower SupplyPower SupplyPower SupplyPower SupplyChassis sold separatelyFansFansF

Page 12

2U Open View:2U Open View:2U Open View:2U Open View:2U Front View:2U Front View:2U Front View:2U Front View:1.Support for up to two GPUs1.Video Port2.

Page 13

Base ModelsBase ModelsBase ModelsBase ModelsHP ProLiant SL390s G7HP ProLiant SL390s G7HP ProLiant SL390s G7HP ProLiant SL390s G72U Left Half Width Tra

Page 14

HP ProLiant SL390s G7 4U ServerHP ProLiant SL390s G7 4U ServerHP ProLiant SL390s G7 4U ServerHP ProLiant SL390s G7 4U ServerPerformance ModelsPerforma

Page 15

HP ProLiant s6500 chassisHP ProLiant s6500 chassisHP ProLiant s6500 chassisHP ProLiant s6500 chassisHP ProLiant s6500HP ProLiant s6500HP ProLiant s650

Page 16

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Page 17

Step 2: Choose Required Node Options (only one of the following from each list unlessStep 2: Choose Required Node Options (only one of the following f

Page 18

HP SL390s G7 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) FIO ProcessorKit611150-L21Dual-Core ProcessorsDual-Core ProcessorsDual-Core ProcessorsDual-C

Page 19

1.2.NOTE:NOTE:NOTE:NOTE: Memory Min and Max depends on number of processors and type of memory:Processor -> R-Dimm: Min 1 // Max 6 U-Dimm: Min 1 //

Page 20

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Page 21

HP ProcessorsHP ProcessorsHP ProcessorsHP ProcessorsSix-Core ProcessorsSix-Core ProcessorsSix-Core ProcessorsSix-Core Processors HP SL390s G7 Intel® X

Page 22

1.2.HP MemoryHP MemoryHP MemoryHP MemoryRegistered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs)Registered DIMMs (RDIMMs) HP 2GB (1

Page 23

1.Support for 4 rear GPUs1.Video Port2.Support for 4 front GPUs2.Serial port (RJ45)3.Eight 2.5" hot plug hard drives3.Power Button 4.10Gb Ether

Page 24

components.NOTE:NOTE:NOTE:NOTE: Hard drives have either a one year or three year warranty.NOTE:NOTE:NOTE:NOTE: The non-hot plug hard drives use a quic

Page 25

HP 300GB 6G SAS 15K rpm LFF (3.5-inch) Quick-release Dual Port Enterprise 3yrWarranty Hard Drive585980-B21HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Quick

Page 26

HP NetworkingHP NetworkingHP NetworkingHP NetworkingGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet AdaptersGigabit Ethernet Adapte

Page 27

HP SL Advanced PowerHP SL Advanced PowerHP SL Advanced PowerHP SL Advanced PowerManagerManagerManagerManagerThe SL Advanced Power Manager is an option

Page 28

HP High Performance Computing Linux Value Pack Media KitNOTE:NOTE:NOTE:NOTE: This part number can be used to purchase media including software anddocu

Page 29

HP 512MB P-Series Battery Backed Write Cache Upgrade462967-B21HP 1GB Flash Backed Cache534562-B21HP 512MB Flash Backed Write Cache534916-B21HP 650 mAh

Page 30

HP 1.83m 10A C13 Power CordAF561AHP 1.83m 10A C13 Power CordAF559AHP 1.83m 10A C13 Power CordAF556AHP 2.0m 10A C13 Power CordAF562AHP 2.5m 10A C13 Pow

Page 31

HP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHP 3y Nbd s6500 HW SupportUR398EHP 3y Nbd w/DMR s6500 HW SuppUR399

Page 32

HP ProLiant SL390s G7 ServerHP ProLiant SL390s G7 ServerHP ProLiant SL390s G7 ServerHP ProLiant SL390s G7 ServerNOTE:NOTE:NOTE:NOTE: Memory configurat

Page 33

2 DIMM PerChannel1333*1333*1333*1066 1333*1066/1333**800 800 8001333 1333 1333**Supported at 1333 via setting in ROM based setup utility (RBSU)**2DPC:

Page 34

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryInteg

Page 35

Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model)Standard memory plus optional memory (1 CPU model)

Page 36

UDIMM maximum configurationUDIMM maximum configurationUDIMM maximum configurationUDIMM maximum configuration48GB, consisting of twelve (12) 4GB dual-r

Page 37

1.2.Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Follo

Page 38

4U Tray4U Tray4U Tray4U Tray1-8Up to eight 2.5" hot plug hard drive bays 2U Tray2U Tray2U Tray2U Tray1-4Up to four 2.5" hot plug hard

Page 39

1-2Up to two 3.5" hard drives use quick release carrier1-4Up to four 2.5" hard drives use quick release carrierDrive SupportDrive SupportDri

Page 40

300GB 6G SAS 10K DP300GB 3G SAS 10K DP146GB 6G SAS 15K DP146GB 3G SAS 15K DP146GB 6G SAS 10K DP146GB 3G SAS 10K DP72GB 6G SAS 15K DP72GB 3G SAS 15K DP

Page 41

500GB 6G SAS 7.2K DPUp to 41-4HP Smart Array P212/Zero Memory ControllerHP Smart Array P212/256 MB ControllerHP Smart Array P410/256 MB ControllerHP S

Page 42

SATA Hot Plug Midline (MDL) Solid State DrivesSATA Hot Plug Midline (MDL) Solid State DrivesSATA Hot Plug Midline (MDL) Solid State DrivesSATA Hot Plu

Page 43

HP 750W Common Slot High Efficiency Power Supply KitHP 750W Common Slot High Efficiency Power Supply KitHP 750W Common Slot High Efficiency Power Supp

Page 44

HP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyHP 1200W 12V Hot Plug AC Power SupplyPa

Page 45

NOTE:NOTE:NOTE:NOTE: 130 watt processors are only available on 2U half width tray in s6500 chassis with non-redundant fans and NO GPUs installedNOTE:N

Page 46

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)6.96 x 17.638 x 35.236in (17.68 x 44.8 x 8

Page 47

IdleIdleIdleIdle LWAd6.4 LpAm45dBAOperatingOperatingOperatingOperating LWAd6.7 LpAm51dBAEmissions ClassificationEmissions ClassificationEmissions Cl

Page 48

Environment-friendlyEnvironment-friendlyEnvironment-friendlyEnvironment-friendlyProducts and ApproachProducts and ApproachProducts and ApproachProduct

Page 49

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsFor SL390s 1U half width serverFor SL390s 1U half width serverFor SL390s 1U half width ser

Page 50

Maximum InternalMaximum InternalMaximum InternalMaximum InternalStorageStorageStorageStorage1U Half Width tray1U Half Width tray1U Half Width tray1U H

Page 51

Server Power CordsServer Power CordsServer Power CordsServer Power CordsOne 6' Highline (IEC-IEC) power cord ships standardNOTE:NOTE:NOTE:NOTE: H

Page 52

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight FoundationManaging the