Vue de la page 112
3-68 Diagnostic Tools
Compaq Integrated Remote Console
The standard Compaq Integrated Remote Console performs a wide range of configuration
activities. Some of the console’s features include
Accessible using ANSI terminal
Operates independently of the operating system
Provides for remote server reboot
Provides access to system configuration
Uses out-of-band communication with dedicated management modem installed in
the server
For more information, see the Integrated Remote Console User Guide,that shipped with your
server.
IMPORTANT:
Before configuring ASR-2, verify that the System
Configuration Utility and Diagnostics software are installed on the system
partition. ASR-2 must have this to start Compaq Utilities after a system
restart. Compaq recommends this even if you configure ASR-2 to start the
operating system.
Compaq Health Driver
The Compaq Health Driver continually resets the ASR-2 timer according to the frequency you
specified in the System Configuration Utility (for example, 10 minutes). If the ASR-2 timer
counts down to zero before being reset, due to an operating system crash or a server lock-up,
ASR-2 restarts the server into either Compaq Utilities or the operating system (as indicated by
the System Configuration parameters). The default value is 10 minutes. The allowable settings
are 5, 10, 20, and 30 minutes.
For remote and off-site (unattended) servers, setting the software error recovery time-out for 5
minutes reduces the server downtime and allows the server to recover quickly. For local
(attended) servers located onsite, you can set the software error recovery time-out for 20 or 30
minutes, giving you time to arrive at the server if you wish to manually diagnose the problem.
The Compaq Health Driver is independent of the ASR-2 timer. You should load it enabling
the ASR-2 timer. This allows the driver to detect and log information about numerous
hardware and software errors in the IML. However, you cannot enable the ASR-2 timer
without loading the Compaq Health Driver.
Before ASR-2 restarts the server, it will record any information available about the condition
of the operating system in the Critical Error Log, or the IML depending on the server support.
This information can be used to diagnose an operating system crash or server lock-up, while
still allowing the server to be restarted.