Removal and Replacement Procedures 2-33
Replacing the Server Feature Board Battery
WARNING: The Server Feature Board contains a lithium battery. There is a risk of fire and
chemical burn if the battery is improperly handled. Do not disassemble, crush, puncture, or
short external contacts, dispose of in water or fire, or expose the battery to temperatures higher
than 60°C (140°F).
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you
are properly grounded (earthed) before beginning any installation procedure. See “Electrostatic
Discharge Information” earlier in this chapter for more information.
To replace the lithium coin cell battery from the Server Feature Board:
1. Complete the preparation procedures. See “Preparation Procedures” earlier in this chapter.
2. Remove the front bezel. See “Front Bezel” earlier in this chapter.
3. Remove the access panel. See “Access Panel” earlier in this chapter.
4. Remove the Server Feature Board. See “Server Feature Board” earlier in this chapter.
5. Locate the battery on the Server Feature Board, and then slide the battery out of the
holder.
6. Slide the replacement battery into the proper position with the positive (+) side up.
Figure 2-29. Locating and removing the battery from the Server Feature Board
IMPORTANT: Positive (+) polarity must be positioned up.
7. Replace the Server Feature Board, front panel, and bezel.
8. Connect the server and power up.
9. For the ProLiant ML330 server, run the BIOS Setup utility to reconfigure your system.
10. For the ProLiant ML330e server, run the RBSU to reconfigure your system.