Compaq StorageWorks 1000 - Modular Smart Array Manuel de service Page 67

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 122
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 66
Determining wh
ether a component is hot-pluggable
Before removin
g any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable.
If the component is hot-pluggable, a power shutdown of the device is not required for replacement
of the part.
If the component is not hot-pluggable, the device must be powered down.
CAUTION:
Be sure the rep
lacement is available before removing a component or blanking panel from the chassis.
Open slots dr
amatically impact airow and cooling within the enclosure.
Table 3 Component hot-pluggability
Component
Hot-pluggable Non hot-pluggable
Redundant power supply/fan assembly
X
MSA array controller
(dual-controller congurations)
X*
Fibre Channel I/O module
(dual-controller congurations)
X*
SCSI I/O module
X
MSA chassis
X
Power switch module
X
MSA array controller
(single-controller congurations)
X
Fibre Channel I/O module
(single-controller congurations)
X
* Before removing one of the two controllers or Fibre Channel I/O modules in an operational dual-controller
MSA, the controller being removed must rst be disabled. For more information, see Replacing the controller,
controller cache, or controller battery .
maintenance and service guide
67
Vue de la page 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 121 122

Commentaires sur ces manuels

Pas de commentaire