Physical
Characteristics
Dimensions
(HxWxD)
5.1 x 17.6 x 19 in/13 x 45 x 48 cm
Weight
36 lbs/16.3 kg
System Unit
Environmental
Temperature
Operating
(Tower, Rackmount)
50
°
to 104
°
F/10
°
to 40
°
C
Note: Maximum operating temperature at sea level. Reduce
by 1.8
°
F (1
°
C) for each 2,000 ft (660 m) above sea level.
Non-operating
–40
°
to 151
°
F/–40
°
to 66
°
C
Humidity
Operating
10% to 95%
Non-operating
20% to 80%
Heat Dissipation
Single unit = 176 Watts = 601 BTU/Hr
Rack of 12 systems = 2112 Watts = ~7,212 BTU/Hr
Typical System
AlphaServer DS10 600 MHz
Power Supply, 300W
Main logic board containing Alpha CPU, EV6, 466 MHz
Main memory = 1 GB
(3) Hard disk drive
(1) Floppy disk drive
(1) CD-ROM disk drive
(1) PCI Graphics Card
(1) PCI Graphics Card
Running system exerciser during the power measurement.
Measured Input Voltage = 116 VAC RMS @ 60Hz
Measured Input Current = 2.27 Amps RMS
Measured Input Power = 176 Watts
Altitude
Operating
40,000 ft/12,192 m
(unpressurized)
Non-operating
10,000 ft / 3,048 m
Note: Higher altitudes are possible if maximum operating
temperature is reduced.
Electrical
(Power supplies are universal, PFC, auto ranging, 100/240 Vac)
QuickSpecs
Compaq AlphaServer DS10 (466 MHz)
DA - 10398 Worldwide QuickSpecs — Version 28 — 10/3/2001
Page 27