Configuration Procedures 5–21
Configuration Options
Changing the CLI Prompt
To change the CLI prompt, enter a 1- to 16- character string as the new prompt, according
to the following syntax:
SET THIS_CONTROLLER PROMPT = “NEW PROMPT”
If you are configuring dual-redundant controllers, also change the CLI prompt on the
other controller. Use the following syntax:
SET OTHER_CONTROLLER PROMPT = “NEW PROMPT”
NOTE: It is suggested that the prompt name reflect some information about the controllers. For
example, if the subsystem is the third one in a lab, name the top controller prompt, LAB3A and
the bottom controller, LAB3B.
Mirroring cache
To specify mirrored cache, use the following syntax:
SET THIS MIRRORED_CACHE
Adding Disk Drives
If you add new disk drives to the subsystem, the disk drives must be added to the
controllers list of known devices:
To add one new disk drive to the list of known devices, use the following syntax:
ADD DISK DISKNNNNN P T L
To add several new disk drives to the list of known devices, enter the following
command:
RUN CONFIG
Adding a Disk Drive to the Spareset
The spareset is a collection of spare disk drives that are available to the controller should it
need to replace a failed member of a RAIDset or mirrorset.