Compaq 4354R - StorageWorks Enclosure Storage Manuel de service Page 30

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 218
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 29
1–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
Units are divided between the host ports:
Units 0-99 are on host port 1 of both controllers (but accessible only through the active
port).
Units 100-199 are on host port 2 of both controllers (but accessible only through the
active port).
Transparent failover only compensates for a controller failure, and not for failures of either
the Fibre Channel link or host Fibre Channel adapters.
Figure 1–5. Transparent failovernormal operation
CXO7036A
Host
port 1
active
Host
port 2
active
D100 D101 D120D0 D1
Host 1
Switch or hub
Host 2
Switch or hub
Host 3
Controller A
Controller B
Host
port 2
standby
Host
port 1
standby
Vue de la page 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 217 218

Commentaires sur ces manuels

Pas de commentaire