Troubleshooting 4-11
9. Push the controller in as far as it will go and close both latches
against the rear panel
. The levers on each latch should catch behind
the metal lip, drawing the board into position and securing it into place.
1
2
2
Figure 4-14. Installing the RA4000 Controller
10. Replace the GBIC and connect the Fibre Channel cable.
11. Reconnect the power cords.
12. Power up the RA4100.
13. Power up the servers attached to the RA4100.
The fault LED on the front panel of the RA4100 should now be green,
indicating a fully functioning system.
Replacing the RA4000 Controller with Redundant
Controller
1. Remove the Fibre Channel cable attached to the GBIC in the failed
RA4000 Controller.
2. Squeeze the tabs on either side of the GBIC , then remove the GBIC
by pulling it straight out of the RA4000 Controller
.