Troubleshooting 4-25
4. Insert the new drive into the same bay as the drive just removed, sliding
it in as far as it will go
. Make sure the ejector lever is in the full open
position to ensure a correct latch.
5. Close the ejector lever against the front of the drive. The locking hinge
must be engaged behind the front panel of the unit.
The drive tray LEDs light one at a time and then turn off together to indicate
that the system has recognized the new drive. In fault-tolerant configurations,
allow the replacement drive to be reconstructed automatically with data from
the other drives. While reconstruction is in progress, the Online LED flashes
(see Figure 4-27).