Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Manuel de service Page 79

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 422
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 78
Figure 3–4: DS-DWZZH-05 Front View
Fair Disable
Host Port
SCSI ID
1
(13)
Host Port
SCSI ID
3
(15)
Controller
Port
SCSI ID
6 - 4
(6 - 0)
Busy
0
2
ZK-1447U-AI
Host Port
Host Port
SCSI ID
SCSI ID
(14)
Power
(12)
3.6.1.2.4 SCSI Bus Termination Power
Each host adapter that is connected to a DS-DWZZH-05 UltraSCSI hub
port must supply termination power (termpwr) to enable the termination
resistors on each end of the SCSI bus segment. If the host adapter is
disconnected from the hub, the port is disabled. Only the UltraSCSI bus
segment losing termination power is affected. The remainder of the SCSI
bus operates normally.
3.6.1.2.5 DS-DWZZH-05 Indicators
The DS-DWZZH-05 has two indicators on the front panel. (See Figure 3–4.)
The green LED indicates that power is applied to the hub. The yellow LED
indicates that the SCSI bus is busy.
Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 3–15
Vue de la page 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 421 422

Commentaires sur ces manuels

Pas de commentaire