Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Manuel de service Page 97

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 422
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 96
Table 3–6: Hardware Components Used in the Configurations Shown in
Figure 3–9 through Figure 3–12
Callout Number
Description
1
BN38C HD68-to-VHDCI cable.
a
A BN38E-0B
technology adapter cable may be connected to a BN37A
cable and used in place of a BN38C cable.
b
2
BN37A VHDCI cable
c
3
BN37A-0E 50-centimeter (19.7-inch) VHDCI cable
d
a
The maximum length of the SCSI bus segment, including the combined length of BN38C cables and
internal device length, must not exceed 25 meters (82 feet).
b
The maximum length of the SCSI bus segment, including the combined length of BN38E-0B and BN37A
cables and internal device length, must not exceed 25 meters (82 feet).
c
The maximum length of the SCSI bus segment, including the BN37A cables and internal device length,
must not exceed 25 meters (82 feet).
d
This cable is used only in the configuration shown in Figure 3–12.
Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 3–33
Vue de la page 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 421 422

Commentaires sur ces manuels

Pas de commentaire