1-8 Compaq AlphaServer ES40 Owner’s Guide
1.5
Operator Control Panel
The control panel provides system controls and status indicators. The
controls are the Power, Halt, and Reset buttons. A 16-character back-
lit alphanumeric display indicates system state. The panel has two
LEDs: a green Power OK indicator and an amber Halt indicator.
Figure 1–5 Operator Control Panel
PK0204
1
2 3 4 5 6
Control panel display. A one-line, 16-character alphanumeric display that
indicates system status during power-up and testing. During operation, the
control panel is back lit.
Power button. Powers the system on and off.
If a failure occurs that causes the system to shut down, pressing the power
button off and then on clears the shutdown condition and attempts to power
the system back on. Some conditions that prevent the system from
powering on can be determined by entering the env command from the
remote management console (RMC). The RMC is powered separately from
the rest of the system and can operate as long as AC power is present. (See
Chapter 4.)