Firmware 5-23
5.5.7 Displaying the Power Status
Use the show power command to display the status of power supplies,
fans, and system temperature. If you are not able to access SRM, in-
voke RMC and issue the env command.
Example 5–8 Show Power
P00>>> show power
Status
Power Supply 0 Good
Power Supply 1 Good
Power Supply 2 Not Available
System Fan 1 Good
System Fan 2 Good
System Fan 3 Bad
System Fan 4 Good
System Fan 5 Good
System Fan 6 Good
CPU 0 Temperature Warning
CPU 1 Temperature Good
CPU 2 Temperature Good
CPU 3 Temperature Good
Zone 0 Temperature Good
Zone 1 Temperature Good
Zone 2 Temperature Good
P00>>>
Power supplies. Power supply 2 is not installed.
System fans. Fan 3 is not working.
Temperature sensors on CPUs. CPU 0 is above threshold.