Compaq AlphaServer ES45 3B Spécifications Page 289

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 322
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 288
Troubleshooting 7-11
7.4 SRM Diagnostics
The SRM console event log and SRM console commands help you
troubleshoot problems that do not prevent the system from coming up
to the console.
7.4.1 Console Event Log
A console event log consists of status messages received during power-
up self-tests. If problems occur during power-up, error messages
indicated by asterisks (***) may be embedded in the console event log.
To display a console event log one screen at a time, use the more el
command.
Example 7–3 shows a console event log with errors. CPU 1 did not power up and
fans 1 and 2 failed.
Example 7–3 Sample Console Event Log
>>>moreel
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPUSROMsync =0
***Error-Fan1failed***
***Error-Fan2failed***
Vue de la page 288
1 2 ... 284 285 286 287 288 289 290 291 292 293 294 ... 321 322

Commentaires sur ces manuels

Pas de commentaire