COMPAQ StorageWorks Upgrading From an HSZ70 to an HSG80 Array Controller
Page 20 EK-HSG80-UP. B01
13.0 Upgrading the Client
Use the following steps to upgrade the server components:
1. Install the Version 8.3 SWCC client kit, especially the following components:
• HSG80 Storage Window
• HSG80 CLI Window
2. If the configuration has already been restored and the HSG80 Logical Units created, skip to
section 14. If the configuration was not restored from the saved configuration or recreated
using CLI commands the configuration that was saved with the previous version of SWCC
can now be restored using the following menu sequence:
• Start the StorageWorks Command Console.
• From the File menu select Add System and add the system name where the upgrade is
taking place.
• Close the Add System Window.
• Open that systems’ folder.
• Open the HSG80 Storage folder.
• Open the Storage Window.
• On the Storage Window select the Controller Configuration menu item.
• Select Load.
• Select Load Configuration Only.
• Then browse for the configuration file that you saved in Section 5.
3. Depending upon the storageset configuration, the restore may require up to 10 minutes. Only
the storageset configuration is restored. Controller parameters and unit numbers are HSG80
specific and are not restored from the HSZ70 saved configuration data.
4. The controller(s) will restart a number of times as the configuration is restored—please be
patient.
5. Once the storagesets have been recreated use the SWCC CLI Window to create the units
from the recreated storagesets. Consult the HSZ70 Host Device Name Table completed in
Section 4. Add the units as needed. Create an HSG80 unit to correspond to the previously
used HSZ70 units. At this time, fill-in the HSG80 unit numbers in the table as they are
created. Substitute the storageset name from the table for the storage set name in the
following commands. Assign the unit numbers in accordance with the recommendations or
restrictions described in the Installation Reference Guide for your server.
Unit numbers on host port 1 are in the range D1 through D99.
Unit numbers on host port 2 are in the range D100 through D199.
The Command Console LUN (CCL) if enabled is unit D0.
HSG80> ADD UNIT D1 storage set name WRITE_BACK
HSG80> ADD UNIT D100 storage set name WRITE_BACK
6. After all of the storagesets have been recreated use the SWCC CLI Window to save all of the
new configuration data with these commands. Identify a unit that has “configuration backed
up on this container.” For example D2:
HSG80> SET D2 WRITE_PROTECT
HSG80> SET D2 NOWRITE_PROTECT