Compaq ProLiant Storage System U1 Guide de l'utilisateur Page 68

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 110
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 67
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9 Troubleshooting
Compaq ProLiant Storage System /U User Guide
Power Supply
The power supply in the ProLiant Storage System /U is pluggable. This means
that the supply may be easily replaced by simply unplugging it and plugging in
a replacement. Select the procedure to follow depending on whether or not the
system has a redundant power supply option installed.
WARNING:
To reduce the risk of injury or damage to the equipment,
observe the following precautions when connecting and disconnecting powe
r
to the power supplies:
Install the power supply before connecting the power cord to the
power supply.
Unplug the power cord before removing the power supply from
the equipment.
To completely remove power from a system, unplug all power cords
from the power supplies.
Single Power Supply Systems
The procedure to replace a power supply in a ProLiant Storage System /U with
a single power supply is as follows:
1. Perform a normal system shutdown for the server(s) supporting the
storage system.
2. Turn OFF the server, then place the storage system in STANDBY (front
panel power switch).
3. Shut off power or remove the AC power cord from the power supply
before replacing it.
Vue de la page 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 109 110

Commentaires sur ces manuels

Pas de commentaire