Vue de la page 198
Managing the System Remotely 6-11
Table 6-2 RCM Status Command Fields
Item Description
Firmware Rev: Revision of RCM firmware.
Escape Sequence: Current escape sequence to invoke RCM.
Remote Access: Modem remote access state. (ENABLE/DISABLE)
Temp (C): Current system temperature in degrees Celsius.
RCM Power Control: Current state of RCM system power control. (ON/OFF)
RCM Halt: Asserted indicates that halt has been asserted with the
haltin command. Deasserted indicates that halt has
been deasserted with the haltout command or by
cycling power with the On/Off button on the control
panel. The RCM Halt: field does not report halts
caused by pressing the Halt button.
External Power: Current state of power to RCM. Always on.
Server Power: Indicates whether power to the system is on or off.