QuickFind Diagnostic Display LEDs
The QuickFind Diagnostic Display is located on the top of the access panel and displays the node
internal component and temperature status.
ActionStatusDescriptionItem
Be sure fan is installed and seated properly.
If fan is installed and seated properly, replace the fan.
Off = Normal
On = Attention
required
Fan1
Processor pre-failure notification. Inspect the IML logs
and POST messages.
Processor might need to be replaced.
Off = Normal
On = Attention
required
Processor2
Processor memory board power failure.
If problem persists, replace the processor or processor
memory board.
Off = Normal
On = Attention
required
Processor memory
board
3
PPM power failure. If problem persists, replace PPM.
If the PPM and the BRD LEDs are both on, there is a
configuration error.
Off = Normal
On = Attention
required
Processor power
module
4