Power-Up Diagnostics and Display 3-19
3.3.4 SRM Console Event Log
The SRM console event log helps you troubleshoot problems that do not
prevent the system from coming up to the SRM console. The console
event log consists of status messages received during power-up self-
tests.
Example 3–4 Sample Console Event Log
>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPU SROM sync = 0
*** Error - Fan 1 failed ***
*** Error - Fan 2 failed ***
If problems occur during power-up, error messages indicated by asterisks (***)
may be embedded in the console event log. To display the console event log one
screen at a time, use the more el command.
Example 3–4 shows a console event log that shows errors. The console reported
that CPU 1 did not power up and fans 1 and 2 failed.