3-28 Compaq AlphaServer ES40 Service Guide
3.4.4 RMC Error Messages
Table 3–2 lists the fatal error messages that could potentially be
displayed on the OCP by the remote management console during
power-up. Most fatal error messages prevent the system from
completing power-up. The warning messages listed in Table 3–3
require prompt attention but might not prevent the system from
completing power-up or booting the operating system.
Table 3–2 RMC Fatal Error Messages
Message Meaning
AC loss No AC power to the system.
CPUn failed
CPU failed. “n” is 0, 1, 2, or 3.
VTERM failed No VTERM voltage to CPUs.
CTERM failed No CTERM voltage to CPUs.
Fan5, 6 failed Main fan (6) and redundant fan (5) failed.
OverTemp failure System temperature has passed the high threshold.
No CPU in slot 0 Configuration requires that a CPU be installed in slot 0.
CPU door opened System card cage cover off. Reinstall cover.
TIG error Code essential to system operation is not loaded and/or
running or TIG flash is corrupt..
Mixed CPU types
Different types of CPU are installed. Configuration
requires that all CPUs be the same type.
Bad CPU ROM data Invalid data in EEROM on the CPU.
NOTE: The“ CPUn failed” message does not necessarily prevent the completion
of power-up. If the system finds a good CPU, it continues the power-up
process.