4–35
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
An unpartitioned storage unit has more capacity than a partition that uses the whole
unit because each partition requires five blocks of administrative metadata. Thus, a
single disk unit that contains one partition can store n-5 blocks of user or application
data.
See “Guidelines for Partitioning Storagesets and Disk Drives,” page 4–35, for
information on manually partitioning a storageset or single-disk unit.
Guidelines for Partitioning Storagesets and
Disk Drives
Keep these points in mind as you plan your partitions:
You can create up to eight partitions per storageset or disk drive.
All of the partitions on the same storageset or disk drive must be addressed
through the same controller port. This ensures a transparent failover of devices
should one of the dual-redundant controllers fail.
Partitions cannot be combined into storagesets. For example, you cannot divide a
disk drive into three partitions, then combine those partitions into a RAIDset.
Partitioned storagesets cannot function in multiple-bus failover dual-redundant
configurations. Because they are not supported, you must delete your partitions
before configuring the controllers for multiple-bus failover.
Once you partition a container, you cannot unpartition it without reinitializing the
container.
Just as with storagesets, you do not have to assign unit numbers to partitions until
you are ready to use them.