Compaq HSG80 - StorageWorks RAID Array Controller Spécifications Page 333

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 396
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 332
7–137
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
This example shows how to display a complete listing of the mirrorset named
MIRR1:
SHOW MIRR1
Name Storageset Uses Used by
------------------------------------------------------------------------------
MIRR1 mirrorset DISK50300 S0
DISK60300
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
COPY (priority) = NORMAL
READ_SOURCE = LEAST_BUSY
MEMBERSHIP = 2, 2 members present
State:
NORMAL
DISK60300 (member 0) is NORMAL
DISK50300 (member 1) is NORMAL
Size: 17769177 blocks