Compaq HSG80 - StorageWorks RAID Array Controller Spécifications Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 396
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
2–15
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Table 2–3. Resulting Cache Policies and ECB Status
ECB Status Cache Policy
Cache A Cache B Unmirrored Cache Mirrored Cache
At least
50%
charged
At least
50%
charged
Data loss: No
Cache policy: Both controllers continue
to support write-back caching.
Failover: No
Data loss: No
Cache policy: Both controllers
continue to support write-back
caching.
Failover: No
Less than
50%
charged
At least
50%
charged
Data loss: No
Cache policy: Controller A supports
write-through caching only;
controller B supports write-back
caching.
Failover: In transparent failover, all
units failover to controller B.
In multiple-bus failover with host-
assist, only those units that use write-
back caching, such as RAIDsets and
mirrorsets, failover to controller B.
In single configurations, the controller
only provides write-through caching to
its units.
Data loss: No
Cache policy: Both controllers
continue to support write-back
caching.
Failover: No
Vue de la page 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 395 396

Commentaires sur ces manuels

Pas de commentaire