7–40
CLI Commands
CLEAR_ERRORS
unit-number
LOST_DATA
Clears lost data errors on a unit; all partitions on the units container are affected.
The controller reports a lost data error on the unit when you remove a write-back
cache module or when the cache module contains unflushed data, possibly due to an
interruption in the primary power source with no backup power present. The
CLEAR_ERRORS LOST_DATA command clears the lost data error but does not
recover the lost data.
NOTE: Clearing lost data errors or lost data block errors on a RAIDset causes a
reconstruction of all parity blocks. Clearing lost data errors or lost data block errors
on a mirrorset causes members to normalize.
Syntax
CLEAR_ERRORS unit-number LOST_DATA
Spell out LOST_DATA when using this command.
CAUTION: This command may cause data loss.
Parameters
unit-number
Identifies the unit on which the lost data error is to be cleared. The unit-number is the
same name given to the unit when you added it to the controller’s configuration.
Example
The following command will clear the lost data error on disk unit number D103:
CLEAR_ERRORS D103 LOST_DATA