7–36
CLI Commands
CLEAR_ERRORS
controller
INVALID_CACHE
Clears an invalid cache error and allows the controller and cache to resume operation.
If the error is due to an incorrectly-mirrored configuration, the controller indicates
mirrored mode status after the error is cleared.
Use this command for the following situations:
■ When the controller or cache modules have been replaced, resulting in
mismatched data between the controllers.
■ When the controller or cache module is replaced while data is still in cache and
not properly flushed with the SHUTDOWN or SET NOFAILOVER COPY=
commands.
Syntax
CLEAR_ERRORS controller INVALID_CACHE
Spell out INVALID_CACHE when using this command.
Parameters
controller
Identifies which controller is to receive the CLEAR_ERRORS command. You must
specify THIS_CONTROLLER or OTHER_CONTROLLER.
data-retention-policy
DESTROY_UNFLUSHED_DATA
NODESTROY_UNFLUSHED_DATA (Default)
Instructs the controller on how to handle write-back cached data.
Specify NODESTROY_UNFLUSHED_DATA (default) to retain the cached data and
discard controller information.