Compaq External RAID Controller & Subsystem Manuel d'utilisateur Page 135

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 347
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 134
Infortrend
7-16
Adding a Global Spare Drive
A global spare replaces the failed drive in any logical drive of a
RAID system.
Move cursor bar to the SCSI drive that is not a member drive or a
spare (usually indicated as a "New Drive"), and then press
[ENTER]. Choose “Add Global Spare Drive.” When prompted to
“Add Global Spare Drive?”, choose Yes.
7.9 Viewing and Editing Logical Drive and
Drive Members
Choose “View and Edit Logical Drives” in the main menu. The array
status will be displayed. Refer to the previous chapter for more
details on the legends used in Logical Drive’s Status. To see the
drive member information, choose the logical drive by pressing
[ENTER].
Choose “View SCSI Drives.” Drive member information will be
displayed on the screen.