Enabling the S.M.A.R.T. Feature
Follow the procedure below to enable S.M.A.R.T. on all drives.
1. First, enable the “Periodic Drive Check Time” function. In
\View and Edit Configuration Parameters\Drive-side SCSI
Parameters\Periodic Drive Check Time, choose a time interval.
2. In \View and Edit Configuration Parameters\Drive-side SCSI
Parameters\Drive Predictable Failure Mode <SMART>, choose one
from “Detect Only,” “Detect, Perpetual Clone” and “Detect,
Clone+Replace.”
Examining Whether Your Drives Support S.M.A.R.T.
To see if your drive supports S.M.A.R.T., follow the steps below:
3. Enable “S.M.A.R.T.” for your drives in the RAID system.
4. In “View and Edit SCSI Drives,” choose one drive to test to.
Press [ENTER] on the drive, a sub-menu will appear.
5. Note that a new item “Predictable Failure Test” appears in the
sub-menu. If the SMART” feature is not properly enabled, this item
will not appear in the sub-menu.