Vue de la page 161
Infortrend
7-43
SCSI Drive Low-level Format
Choose “SCSI Drive Low-level Format” and confirm by selecting
Yes.
IMPORTANT!
•
Do not switch the controller’s and/or SCSI disk drive’s power off during
the SCSI Drive Low-level Format. If any power failure occurs during the
formatting process, the formatting must be performed again when power
resumes.
•
All data stored in disk drives will be destroyed during the low-level
format.
•
The disk drive on which a low-level disk format will be performed cannot
be a spare drive (local or global) nor a member of a logical drive. The
"SCSI Drive Low-level Format" option will not appear if the drive is not
indicated as a "New Drive" or a "Used Drive." Also, a drive formatted
with a 256MB reserved space is also excluded from selection.