Front Panel Operation
5-30
Setting Transfer Width
The controller supports 8-bit SCSI and 16-bit SCSI. Enable “Wide
Transfer” to use the 16-bit SCSI function. Disabling “Wide Transfer”
will limit the channel transfer speed to 8-bit SCSI.
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit SCSI Channels," then
press ENT.
Channel information will be displayed.
Press or to browse through the
channels. Press ENT on the channel
you wish the transfer width changed.
Press or to select “Set Transfer
Width," then press ENT.
The current mode will be displayed.
Press ENT to continue.
Press ENT again for two seconds.
IMPORTANT!
Every time you change the SCSI Transfer Width, you must reset the
controller for the changes to take effect.
Viewing and Editing SCSI Target - Drive Channel
Press ENT for two seconds to enter the
Main Menu. Press or to select
"View and Edit SCSI Channels," then
press ENT.
SCSI channel information will be
displayed on the LCD. Press ENT on
the drive channel you wish the SCSI ID
changed.
View and Edit
SCSI Channels
View and Edit
SCSI Channels
CH0=Host PID=0
SID=NA SXF=20.0M
CH1=Drive PID=7
SID=NA SXF=20.0M
Set Transfer
Width ..
View and Edit
SCSI Target ..
Wide Transfer
Enabled ..
Disable
Wide Transfer ?