7.12 Viewing and Editing SCSI Channels
Except for those shipped in dual-redundant chassis, SCSI-based
controllers use channel 0 as the host channel and also as the
communications path between controllers. If redundant controller
configuration is preferred, you may need to assign other channels as
host. Flexibility is added for all channels can be configured as host
or drive.
Choose “View and Edit SCSI Channels” in the main menu. Channel
status displays.
Redefining Channel Mode
For Fibre and SCSI-based controllers, all channels can be operated in
host or drive mode. Choose the channel you wish to change, then
press [ENTER]. Choose “Channel Mode,” then press [ENTER]. A
dialog box will appear asking you to confirm the change.
IMPORTANT!
Every time you change the channel mode, you must reset the controller for
the change to take effect.