Infortrend10-28
Choose "Redundant Controller [Function]," and then press [ENTER]. (Note:
The current setting will be displayed on the screen. If this controller has
never been set as a redundant controller before, the default setting is
"Disabled". The message "Redundant Controller - Disabled" will be
displayed on the screen. Press [ENTER] to proceed.)
The message "Enable Redundant Controller in Autoconfigure Mode" will
appear. Use the arrow keys to scroll through the available options
("Primary," "Secondary," or "Autoconfigure"). Press [ENTER] on "Primary."
• Power off controller 1, then power on controller 2. Set controller 2 to
"Secondary" as described above.
• Power off controller 2.
• Power on drives, both controllers, and host computer(s) for the settings
to take effect.
• The Primary and Secondary controllers synchronize each other’s
configurations at frequent intervals through the established
communications path(s). Write-back cache will be disabled if no sync.
cache path exists.
• Select "View and Edit SCSI Channels" from the Main Menu, the
communications path will be displayed as "RCCOM (Redundant
Controller Communications)."