Compaq HSG80 - StorageWorks RAID Array Controller Spécifications Page 122

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 121
4–16 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
Table 4–3 Resulting Cache Policies—ECB Status
Cache Module Status Cache Policy
Cache A Cache B Unmirrored Cache Mirrored Cache
At least
50%
charged.
At least
50%
charged.
Data loss: No.
Cache policy: Both controllers continue to
support write-back caching.
Failover: No.
Data loss: No.
Cache policy: Both controllers continue to
support write-back caching.
Failover: No.
Less than
50%
charged.
At least
50%
charged.
Data loss: No.
Cache policy: Controller A supports
write-through caching only; controller B
supports write-back caching.
Failover: In transparent failover, all units
failover to controller B.
In multiple-bus failover with host-assist,
only those units that use write-back
caching, such as RAIDsets and mirrorsets,
failover to controller B.
In single-controller configurations, the
controller only provides write-through
caching to its units.
Data loss: No.
Cache policy: Both controllers continue to
support write-back caching.
Failover: No.
Failed. At least
50%
charged.
Data loss: No.
Cache policy: Controller A supports
write-through caching only; controller B
supports write-back caching.
Failover: In transparent failover, all units
failover to controller B and operate
normally.
In multiple-bus failover with host-assist,
only those units that use write-back
caching, such as RAIDsets and mirrorsets,
failover to controller B.
In single-controller configurations, the
controller only provides write-through
caching to its units.
Data loss: No.
Cache policy: Both controllers continue to
support write-back caching.
Failover: No.
Vue de la page 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 295 296

Commentaires sur ces manuels

Pas de commentaire