Vue de la page 71
2–44 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
12. Press Return to resume device port activity and restart the “other controller.” When all
port activity has restarted, The following display appears:
PVA replacement complete.
Please wait . . .
If the other controller did not restart, press its reset button.
Field Replacement Utility terminated.
13. If the “other controller” did not restart, press its reset button.
14. Enable failover and re-establish the dual-redundant configuration with the following
command:
SET FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystems configuration from “this controller” to the
“other controller.”