Compaq HSG80 - StorageWorks RAID Array Controller Spécifications Page 217

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 216
Event Reporting: Templates and Codes 5–53
01970188 Software indicates all NMI causes cleared, but some remain.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
Last Failure Parameter [6] contains the PCFX PDAL control / status register.
Last Failure Parameter [7] contains the PCFX CDAL control / status register.
01
01982087 The Ibus encountered a parity error.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
Last Failure Parameter [6] contains the RIP.
20
01992088 An error was detected by the PLX.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PLX status register.
Last Failure Parameter [6] contains the previous PDAL address of error register.
Last Failure Parameter [7] contains the RIP.
20
Table 5–18 Last Failure Codes (Sheet 7 of 41)
Code Description
Repair
Action
Code
Vue de la page 216