2–50 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
Replacing DIMMs
Use the following steps in “Removing DIMMs” and “Installing DIMMs” to replace
DIMMs in a cache module. DIMM locations are shown in Figure 2–14 and supported
configurations are shown in Table 2–1.
Figure 2–14. Cache module DIMM locations
CAUTION: ESD can easily damage a cache module or a DIMM. Wear a snug-fitting,
grounded ESD wrist strap.
NOTE: If a DIMM fails, note which DIMM needs replacement based on the diagram displayed on
the console.
CXO6576B
4
2
3
1
Table 2–1 Cache Module Memory Configurations
Memory DIMMs Quantity Location
64 MB 32 MB 2
128 MB 32 MB 4
256 MB 128 MB 2
512 MB 128 MB 4