Compaq HSG80 - StorageWorks RAID Array Controller Spécifications Page 133

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 296
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 132
Troubleshooting Resources 4–27
CLI Event Reporting
CLI event reports are automatically displayed on the maintenance terminal (unless
disabled via the FMU) using %CER formatting, as shown in the following example:
Utilities and Exercisers
Controller software includes utilities and exercisers to assist in troubleshooting and
maintaining the controller and the other modules that support its operation. These utilities
and exercisers include:
Fault management utility (FMU)
Video terminal display (VTDPY) utility
Disk inline exerciser (DILX)
Format and device code load utility (HSUTIL)
Configuration (CONFIG) utiltity
Code load and code patch (CLCP) utility
CLONE utility
Field replacement utility (FRUTIL)
Change volume serial number (CHVSN) utility
Device statistics (DSTAT) utility—not supported
FMU
The FMU provides a limited interface to the controller fault management software. Use
FMU to:
Display the last failure and memory-system-failure entries that the fault management
software stores in the controller non-volatile memory.
Translate many of the code values contained in event messages. For example, entries
might contain code values that indicate the cause of the event, the software component
that reported the event, the repair action, and so on.
%CER--HSG> --13-JAN-1999 04:32:20 (time not set)-- Previous controller-
operation terminated with display of solid fault code, OCP Code: 3F
HSG>
Vue de la page 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 295 296

Commentaires sur ces manuels

Pas de commentaire